Hotline: 0988.816.815     vie    eng

YL9100 Plus HPLC (Analytical HPLC)

YL9100 Plus HPLC (Analytical HPLC)
zoom Zoom image
Price: 0 VND
Manufacturer: Young In - Korea
Quantity: 

Description

YL9100 Plus HPLC is launched to meet an exceptional cost effectiveness by continued research and development. Newly improved YL9110 Plus Quaternary Pump delivers the enhanced mixing performance to provide the very stabilized baseline by reducing noise when it comes to change the solvent composition. With automatic compressibility compensation minimizing flow rate deviation in the pump, YL9100 Plus HPLC ensures superior RT repeatability by providing accurate and precise flow rates.

 

Features

Ultra speed data processing by Network HPLC.
YL-Clarity designed for all you need in the lab.
Enhanced superior performance.
Versatile dedicated applications.
Accurate and reliable data.
Stylish and compact design.
Various modules available:


YL9110 Quaternary Pump / YL9111 Binary Pump / YL9112 Isocratic Pump
YL9101 Vacuum Degasser
YL9131 Column Compartment
YL9120 UV/Vis Detector
YL9140 FL Detector
YL9160 PDA Detector
YL9170 RI Detector
ZAM 4000 ELS Detector

 

Specifications

Vacuum Degasser

  • Maximum flow rate: 10 ml/min per channel
  • Internal volume per channel: 925 ul per channel
  • Solvent contact materials: Teflon AF, PEEK and Glass-filled PTFE

Quaternary Pump

  • Flow range: 0.001-10 ml/min
  • Flow rate accuracy: ≦ ±1% at 1 ml/min
  • Flow rate precision: < 0.1% RSD at 1 ml/min
  • Number of eluent lines: 4
  • Pressure pulsation: ≦ ±0.5% at 1 ml/min

Autosampler

  • Sample capacity: Up to 120 samples (2 ml vial), 80 samples (4ml vial)
  • Carry over: < 0.04% with standard wash

Typically < 0.02% with extra wash

  • Reproducibility: RSD < 0.3% for full loop injections

RSD < 0.5% for partial loopfill injections (injection > 5µL)

RSD < 1.0% for µL pick-up injections (injections volume > 5µL)

  • Injection volume: 0.1 – 400 µL, with 0.1 µL increment
  • Sample cooling: 4 – 40 oC (option)

UV/VIS Detector

  • Wavelength range: 190-600 nm (Standard) /190-900 nm (Option)
  • Spectral bandwidth: 5 nm
  • Wavelength accuracy: ±1 nm
  • Wavelength precision: ±0.1 nm
  • Linearity: > 99.5% at 2.5 AU (Acetone, 254 nm)
  • Noise level: < ±0.35 X 10-5

 AU, 254 nm, dry cell

  • Drift: < 1 X 10‑4 AU/hour

System Information

  • Data communications: LAN
  • Dimension: 375 X 470 X 545 mm (W X H X D)
  • Weight: 27 Kg
  • Safety & maintenance: Leak detection, Diagnostics, Error detection
  • Power consumption: 150 W

YL9330 Column Compartment

  • Temperature range: 4°C (Cooling) 90 °C
  • Temperature stability: ±0.05°C
  • Temperature accuracy: ±0.5°C, with 2-point temp. calibration
  • Temperature programs: 40 Steps
  • Column capacity: three columns up to 300 mm length

                                    (max OD: up to 18 mm)

     Column switching (Option): automatically 6-port SS(PEEK)

                                                       valve up to 2 ea

  • Communications: LAN
  • Safety & maintenance: Leak detection, Diagnostics,

                                                Error detection

  • Dimensions: 185 x 476 x 480 mm (W x H x D)
  • Line voltage: 100-240 VAC, ±10%, automatic voltage selection
  • Line frequency: 50/60Hz, ±5%
  • Power consumption: 150 W

Application


Accessories


Video


Catalogue and User Manual


Download Catalogue
Download User Manual
Copyright MAXXmarketing Webdesigner GmbH