Hotline: 0988.816.815     vie    eng

YL9300 HPLC (Integrated HPLC)

YL9300 HPLC (Integrated HPLC)
zoom Zoom image
Price: 0 VND
Manufacturer: Young In - Korea
Quantity: 

Description

YL9300 HPLC is an integrated HPLC system in a compact design including vacuum degasser, quaternary pump with a mixing valve and UV/VIS detector at a competitive price.


This system provides greatly stabilized baseline with a substantially minimized noise level.


Its newly innovated focus lens in a monochromator reduces mobile phase RI effect effectively which leads the decreased influence by a solvent peak.

 

Features

Integrated LPG HPLC system: Vacuum Degasser + Quaternary Pump + UV Detector
Increased mobile phase composition efficiency
Decreased solvent peak influence
Greatly stabilized baseline with substantially minimized noise level
Simple Maintenance: Pump&Vacuum Degasser modules in a sliding drawer
High speed data process by network (LAN) communication
Competitive or even lower price than others

 

Specifications

Vacuum Degasser

  • Number of channel: 4 CHs
  • Maximum flow rate: 10 ml/min per channel
  • Internal volume per channel: 925 ul per channel
  • Solvent contact materials: Teflon AF, PEEK and Glass-filled PTFE

 

YL9330 Column Compartment

  • Temperature range: 4°C (Cooling)-90 °C
  • Temperature stability: ±0.05°C
  • Temperature accuracy: ±0.5°C, with 2-point temp. calibration
  • Temperature programs: 40 Steps
  • Column capacity: three columns up to 300 mm length

                                    (max OD: up to 18 mm)

     Column switching (Option): automatically 6-port SS(PEEK)

                                                       valve up to 2 ea

  • Communications: LAN
  • Safety & maintenance: Leak detection, Diagnostics,

                                                Error detection

  • Dimensions: 185 x 476 x 480 mm (W x H x D)
  • Line voltage: 100-240 VAC, ±10%, automatic voltage selection
  • Line frequency: 50/60Hz, ±5%
  • Power consumption: 150 W

 

Quaternary bump

  • Flow range: 0.001-10 ml/min
  • Flow rate accuracy: ≦ ±1% at 1 ml/min
  • Flow rate precision: < 0.1% RSD at 1 ml/min
  • Number of eluent lines: 4
  • Pressure pulsation: ≦ ±0.5% at 1 ml/min

UV/VIS Detector

  • Wavelength range: 190-600 nm (Standard) /190-900 nm (Option)
  • Spectral bandwidth: 5 nm
  • Wavelength accuracy: ±1 nm
  • Wavelength precision: ±0.1 nm
  • Linearity: > 99.5% at 2.5 AU (Acetone, 254 nm)
  • Noise level: < ±0.35 X 10-5 AU, 254 nm, dry cell
  • Drift: < 1 X 10-4 AU/hour

System Information

  • Data communications: LAN
  • Dimension: 375 X 470 X 545 mm (W X H X D)
  • Weight: 27 Kg
  • Safety & maintenance: Leak detection, Diagnostics, Error detection

•   Power consumption: 150 W

Application


Accessories


Video


Catalogue and User Manual


Download Catalogue
Download User Manual