STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

  • 1731
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Nhiều loại đầu dò tia X đếm photon đơn.

● Bức xạ Kα1 tinh khiết sử dụng nguồn Co, Cu, Mo và Ag.

● Chế độ truyền/Debye-Scherrer hoặc Bragg-Brentano.

Introduction

The well-known, high-precision STOE STADI P two circle goniometer is the basis of STOE’s powder diffraction building block system (read more about it here). Vertically or horizontally mounted, the STADI P can be built in Transmission/Debye-Scherrer or Bragg-Brentano geometry. Moreover, two STADI P goniometers, either in the same or different configurations, can be mounted in the same cabinet resulting in two completely independent instruments. However, the two goniometers can also share one source.

  • Various single-photon-counting X-ray detectors
  • Pure Kα1 radiation using Co, Cu, Mo and Ag sources
  • The ultimate platform for laboratory PDF calculations using Ag Kα1 data
  • Transmission/Debye-Scherrer or Bragg-Brentano mode
  • Ideally suited for the analysis of air/moisture-sensitive and microsamples
  • A range of high- and low-temperature attachments available
  • ADVANTAGES OF TRANSMISSION-/ DEBYE-SCHERRER GEOMETRY

  • Same sample volume in the beam over the full 2θ scale
  • Reliable intensities with no necessity for further mathematical corrections
  • No line broadening for weak absorbers
  • No height displacement
  • Real micro-sampling possible
  • Lesser effects of preferred orientation

Specifications

stadip sandwich
 
2θ range 0° up to 140° 2θ
Goniometer 2 circles
Radius of measuring circle 260 mm
Radius of focusing circle 130 mm
X-ray sources Sealed Tubes: Co, Cu, Mo, Ag
Optics Primary monochromator
Software WinXPOW package
Dimensions (including system cabinet, max.) 1800 x 880 x 2050 mm
Weight (complete system) 780 – 940 kg
Detectors Silicon strip detector MYTHEN2 R 1K/2K/3K/4K
Accessories
  • High- and low-temperature attachments for reflection and capillary samples
  • Reaction chamber for capillary samples
  • Various sample stages
  • Various sample changers
Powder STADI P DSC 7323 RZ e1686834392423
The STADI P can be set up by itself or as a dual setup with two different geometries on the independent goniometers.
STADIP 1 e1681798921908
The horizontal STADI P set up with a capillary sample holder.
STADIP 2
The horizontal STADI P set up with STOE's transmission sample holder.
Mythen 3K e1686833321953
For ultra fast measurements of e.g. unstable samples STOE offers an installation with up to four MYTHEN detectors. With four MYTHEN detectors a single exposure will cover 0 - 73° in 2θ. (See the respective AppNote)

ADAMAnT

When an X-ray tube ages, it is possible that its take off angle changes, resulting in a 2 Theta shift of the reflex positions on the detector. To reverse the impact of this take off angle change, the monochromator and sample position have to be adapted through a Beam Optimization.
The STOE STADI P Beam Optimization has been a well-established tool of the WinXPOW software for a very long time. It automatically sets the Johann type monochromator to the maximum intensity of the Kα1-radiation of a sealed tube’s line focus by the help of a certified standard material – but the alignment of the goniometer axis into the beam path has – so far – still to be done manually with a luminance screen.
From now on, the unique ADAMAnT tool aligns monochromator and goniometer automated to the Kα1-radiation, making any contact with the open beam or its air scattered radiation no longer necessary, no matter whether it is only the exchange of a worn-out tube by a new one with the same anode material or whether the radiation should be swapped to a different one.
The ADAMAnT is available for all typical anode materials (Co, Cu, Mo, Ag) but currently only for horizontal setups, with plans for future availability in vertical configurations and conveniently, can be integrated into existing horizontal STADI P diffractometers.

StadiP2 reveal new 1536x1536
Rendering of a horizontal STADI P including the hardware for the ADAMAnT

STADi P for pdf data collection

As the demand for materials with lower degrees of order continues to rise, the significance of Pair Distribution Function (PDF) measurements is growing steadily. To measure best possible data for PDF interpretation, the STADI P can be installed with Ag Kα1 radiation and expanded with a PDF collimator, a MYTHEN2 4K detector and optionally air scattering shields, without any loss in diffraction data quality.

PDF comparison Zobel e1681221508789
This direct comparison of PDF data measured on the ionic liquid hmimPF6 shows how excellent our instrument performs versus a synchrotron. Plot from: doi.org/10.1063/1.5093714
STOE Transmission 054 bearb e1686834533942
PDF data is preferably collected in Debye-Scherrer geometry, which is beneficial for air sensitive samples.
PDF1 e1684828024312
With the MYTHEN2 4K detector in one-step mode you can measure up to 144° 2θ (2x 27° simultaneously, see the respective AppNote) in shortest time.
multimythenPDF e1684828157149
Shields can optionally be set on the detectors to reduce additional effects of air scattering
STOE Transmission 070 e1686834558935
For PDF measurements we offer a special collimator to reduce addittional background signal at high angles.

Software & Accessories

WinXPOW, is a uniquely designed powder diffraction software developed exclusively by our skilled team at STOE. It is meticulously crafted to perfectly work with our instruments, ensuring seamless compatibility and optimal performance. In addition to controlling the instruments, WinXPOW provides a comprehensive range of cutting-edge features. These include data reduction, profile fitting, pattern indexing, and spacegroup determination. Moreover, it boasts an array of powerful functionalities, such as advanced 2D and 3D graphics, among numerous other capabilities.

 

We provide a wide range of accessories to customize your sample environment according to your specific requirements. Our products encompass high temperature and reaction chambers, sample changers, dedicated battery cell holders, and various other accessories to enhance your experimentation capabilities.

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: Pnshar - Trung Quốc

Máy kiểm tra độ thoát nước PN-SDJ100A SR là một thiết bị chuyên nghiệp được thiết kế dựa trên phương pháp Schopper-Riegler, dùng để đo chính xác hiệu suất thoát nước của bột giấy. Phiên bản mới nhất của máy kiểm tra độ thoát nước này sử dụng hệ thống điều khiển tự động bằng khí nén.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy kiểm tra độ cứng cốc giấy PN-PCTF được thiết kế và phát triển theo tiêu chuẩn quốc gia GB/T 27590.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy sấy ly tâm điện PN-CD280 là một thiết bị tiên tiến trong ngành công nghiệp sản xuất giấy, được tối ưu hóa cho việc khử nước và sấy khô bột giấy hiệu quả. Thiết bị này tích hợp công nghệ tiên tiến và thiết kế thẩm mỹ. Nó không chỉ dễ vận hành mà còn...
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy phân tích sợi giấy dòng PN-XWY-IX sử dụng kính hiển vi sinh học để phóng đại các sợi bột giấy lên mức độ cao, cho phép quan sát rõ ràng cấu trúc sợi mịn.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy kiểm tra độ thoát nước PN-SDJ100A SR là một thiết bị chuyên nghiệp được thiết kế dựa trên phương pháp Schopper-Riegler, dùng để đo chính xác hiệu suất thoát nước của bột giấy. Phiên bản mới nhất của máy kiểm tra độ thoát nước này sử dụng hệ thống điều khiển tự động bằng khí nén.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy kiểm tra độ thoáng khí của khẩu trang y tế PN-MBT2F được thiết kế theo tiêu chuẩn YY0469-2011 "Yêu cầu kỹ thuật đối với khẩu trang phẫu thuật y tế".
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy kiểm tra khả năng thoáng khí của khẩu trang PN-MRTF được thiết kế theo tiêu chuẩn GB/T 32610-2016 và được sử dụng để kiểm tra khả năng cản trở khi hít vào và thở ra của khẩu trang. Máy kiểm tra này phù hợp với khẩu trang y tế và khẩu trang bảo hộ hàng ngày.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy kiểm tra khả năng thấm hút nước của băng vệ sinh PN-WATF được thiết kế và phát triển bởi công ty chúng tôi theo tiêu chuẩn quốc gia mới nhất GB/T 8939. Máy chủ yếu được sử dụng cho băng vệ sinh nữ (bao gồm cả miếng lót vệ sinh).
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy kiểm tra độ phồng , độ xốp giấy PN-PLTF là một loại thiết bị đo độ độ phồng , độ xốp của các loại giấy gia dụng khác nhau do công ty chúng tôi phát triển theo yêu cầu của khách hàng, chủ yếu bao gồm giấy mềm có hộp bơm, khăn tay, giấy vệ sinh không lõi.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy đo độ dày giấy vệ sinh (tissue) PN-PT12F là thiết bị kiểm tra độ dày giấy vệ sinh được thiết kế và phát triển theo tiêu chuẩn quốc gia GB/T24328.2 và ISO 12625.3, phù hợp cho giấy vệ sinh và các sản phẩm từ giấy vệ sinh.
Liên hệ