STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

  • 1741
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Nhiều loại đầu dò tia X đếm photon đơn.

● Bức xạ Kα1 tinh khiết sử dụng nguồn Co, Cu, Mo và Ag.

● Chế độ truyền/Debye-Scherrer hoặc Bragg-Brentano.

Introduction

The well-known, high-precision STOE STADI P two circle goniometer is the basis of STOE’s powder diffraction building block system (read more about it here). Vertically or horizontally mounted, the STADI P can be built in Transmission/Debye-Scherrer or Bragg-Brentano geometry. Moreover, two STADI P goniometers, either in the same or different configurations, can be mounted in the same cabinet resulting in two completely independent instruments. However, the two goniometers can also share one source.

  • Various single-photon-counting X-ray detectors
  • Pure Kα1 radiation using Co, Cu, Mo and Ag sources
  • The ultimate platform for laboratory PDF calculations using Ag Kα1 data
  • Transmission/Debye-Scherrer or Bragg-Brentano mode
  • Ideally suited for the analysis of air/moisture-sensitive and microsamples
  • A range of high- and low-temperature attachments available
  • ADVANTAGES OF TRANSMISSION-/ DEBYE-SCHERRER GEOMETRY

  • Same sample volume in the beam over the full 2θ scale
  • Reliable intensities with no necessity for further mathematical corrections
  • No line broadening for weak absorbers
  • No height displacement
  • Real micro-sampling possible
  • Lesser effects of preferred orientation

Specifications

stadip sandwich
 
2θ range 0° up to 140° 2θ
Goniometer 2 circles
Radius of measuring circle 260 mm
Radius of focusing circle 130 mm
X-ray sources Sealed Tubes: Co, Cu, Mo, Ag
Optics Primary monochromator
Software WinXPOW package
Dimensions (including system cabinet, max.) 1800 x 880 x 2050 mm
Weight (complete system) 780 – 940 kg
Detectors Silicon strip detector MYTHEN2 R 1K/2K/3K/4K
Accessories
  • High- and low-temperature attachments for reflection and capillary samples
  • Reaction chamber for capillary samples
  • Various sample stages
  • Various sample changers
Powder STADI P DSC 7323 RZ e1686834392423
The STADI P can be set up by itself or as a dual setup with two different geometries on the independent goniometers.
STADIP 1 e1681798921908
The horizontal STADI P set up with a capillary sample holder.
STADIP 2
The horizontal STADI P set up with STOE's transmission sample holder.
Mythen 3K e1686833321953
For ultra fast measurements of e.g. unstable samples STOE offers an installation with up to four MYTHEN detectors. With four MYTHEN detectors a single exposure will cover 0 - 73° in 2θ. (See the respective AppNote)

ADAMAnT

When an X-ray tube ages, it is possible that its take off angle changes, resulting in a 2 Theta shift of the reflex positions on the detector. To reverse the impact of this take off angle change, the monochromator and sample position have to be adapted through a Beam Optimization.
The STOE STADI P Beam Optimization has been a well-established tool of the WinXPOW software for a very long time. It automatically sets the Johann type monochromator to the maximum intensity of the Kα1-radiation of a sealed tube’s line focus by the help of a certified standard material – but the alignment of the goniometer axis into the beam path has – so far – still to be done manually with a luminance screen.
From now on, the unique ADAMAnT tool aligns monochromator and goniometer automated to the Kα1-radiation, making any contact with the open beam or its air scattered radiation no longer necessary, no matter whether it is only the exchange of a worn-out tube by a new one with the same anode material or whether the radiation should be swapped to a different one.
The ADAMAnT is available for all typical anode materials (Co, Cu, Mo, Ag) but currently only for horizontal setups, with plans for future availability in vertical configurations and conveniently, can be integrated into existing horizontal STADI P diffractometers.

StadiP2 reveal new 1536x1536
Rendering of a horizontal STADI P including the hardware for the ADAMAnT

STADi P for pdf data collection

As the demand for materials with lower degrees of order continues to rise, the significance of Pair Distribution Function (PDF) measurements is growing steadily. To measure best possible data for PDF interpretation, the STADI P can be installed with Ag Kα1 radiation and expanded with a PDF collimator, a MYTHEN2 4K detector and optionally air scattering shields, without any loss in diffraction data quality.

PDF comparison Zobel e1681221508789
This direct comparison of PDF data measured on the ionic liquid hmimPF6 shows how excellent our instrument performs versus a synchrotron. Plot from: doi.org/10.1063/1.5093714
STOE Transmission 054 bearb e1686834533942
PDF data is preferably collected in Debye-Scherrer geometry, which is beneficial for air sensitive samples.
PDF1 e1684828024312
With the MYTHEN2 4K detector in one-step mode you can measure up to 144° 2θ (2x 27° simultaneously, see the respective AppNote) in shortest time.
multimythenPDF e1684828157149
Shields can optionally be set on the detectors to reduce additional effects of air scattering
STOE Transmission 070 e1686834558935
For PDF measurements we offer a special collimator to reduce addittional background signal at high angles.

Software & Accessories

WinXPOW, is a uniquely designed powder diffraction software developed exclusively by our skilled team at STOE. It is meticulously crafted to perfectly work with our instruments, ensuring seamless compatibility and optimal performance. In addition to controlling the instruments, WinXPOW provides a comprehensive range of cutting-edge features. These include data reduction, profile fitting, pattern indexing, and spacegroup determination. Moreover, it boasts an array of powerful functionalities, such as advanced 2D and 3D graphics, among numerous other capabilities.

 

We provide a wide range of accessories to customize your sample environment according to your specific requirements. Our products encompass high temperature and reaction chambers, sample changers, dedicated battery cell holders, and various other accessories to enhance your experimentation capabilities.

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: Labthink - Trung Quốc

Máy kiểm tra tốc độ truyền oxy/hơi nước C403M dựa trên nguyên lý kiểm tra của cảm biến oxy điện hóa và cảm biến hơi nước hồng ngoại. Hệ thống được thiết kế và sản xuất theo các tiêu chuẩn như ASTM D3985, ASTM F1249 và ISO 15106-2. Nó cung cấp giải pháp kiểm tra tích hợp độ chính xác cao cho tốc độ truyền hơi nước và oxy của các vật liệu có rào cản cao và trung bình. Hệ thống được ứng dụng rộng rãi trong dược phẩm, thực phẩm, thiết bị y tế, hóa chất tiêu dùng hàng ngày, quang điện, điện tử và các lĩnh vực khác, giúp phát hiện chính xác hiệu suất truyền oxy và hơi nước của màng, bao bì, tấm và các vật liệu liên quan.
Liên hệ

Hãng sx: Labthink - Trung Quốc

Máy phân tích khí trong không gian kín C650H có thiết kế cấu trúc chuyên nghiệp và cảm biến độ chính xác cao, cho phép xác định chính xác và thuận tiện hàm lượng O2 trong các túi kín, chai, lon và các vật chứa bao bì rỗng khác. Đồng thời, với việc lựa chọn các phụ kiện thử nghiệm, máy cũng có thể kiểm tra CO2. Máy phù hợp cho dây chuyền sản xuất, nhà kho, phòng thí nghiệm và các môi trường khác để nhanh chóng và chính xác đánh giá hàm lượng O2 và CO2 trong khí, từ đó hướng dẫn sản xuất.
Liên hệ

Hãng sx: Labthink - Trung Quốc

Dựa trên nguyên lý thử nghiệm của phương pháp phân hủy chân không, được thiết kế và sản xuất theo tiêu chuẩn ASTM F2338 và các tiêu chuẩn khác. Nó phù hợp chuyên nghiệp để phát hiện rò rỉ lọ thuốc và phát hiện rò rỉ theo dõi ống thuốc, chai lọ đựng thuốc, chai truyền dịch, ống tiêm đã nạp sẵn và các bao bì dược phẩm khác.
Liên hệ

Hãng sx: Labthink - Trung Quốc

- Máy cầm tay, đo nhanh và chính xác nồng độ khí oxygen và carbon dioxide (CO2 – tùy chọn) trong bao gói kín, chai và lon - Sử dụng các cảm biến và bơm chính xác của các nhà sản xuất nổi tiếng thế giới
Liên hệ

Hãng sx: Labthink - Trung Quốc

Thiết bị kiểm tra momen lực NJY-20 được thiết kế để kiểm tra lực mở và đóng nắp chai, lọ, túi có vòi và các loại đóng gói dạng tuýp khác. Sự chính xác và ổn định của thiết bị khiến nó trở thành một trong những máy đo không thể thiếu trong quy trình sản xuất ở các nhà máy.
Liên hệ

Hãng sx: Labthink - Trung Quốc

- Phù hợp tiêu chuẩn ASTM D3078 - Cài đặt trước và duy trì đúng độ chân không - Xả ngược khi kết thúc, sẵn sàng cho thí nghiệm tiếp theo
Liên hệ

Hãng sx: Labthink - Trung Quốc

- Phương pháp áp suất âm, phù hợp tiêu chuẩn ASTM D3078 - Nhiều chế độ kiểm tra: tiêu chuẩn, chân không đa cấp và methylthionine chloride - Điều chỉnh và lưu lại các thông số vận hành
Liên hệ

Hãng sx: Labthink - Trung Quốc

- Máy kiểm tra hàn dán nhiệt (Heat Seal Tester) dùng để hàn nhiệt cho các màng mỏng sử dụng làm bao bì dưới điều kiện điều khiển chính xác nhiệt độ, áp lực và thời gian - Máy kiểm tra hàn dán nhiệt (Heat Seal Tester) là công cụ không thể thiếu để kiểm tra nguyên liệu sản xuất bao bì và để điều chỉnh dây chuyền đóng gói sản phẩm cho phù hợp
Liên hệ

Hãng sx: Labthink - Trung Quốc

Máy đo lực kéo C610 là máy kiểm tra chuyên nghiệm được sử dụng để đo lực kéo, bóc tách, biến dạng, xé rách, hàn dán, dính, lực đâm thủng, lực mở, lực kéo, lực mở tốc độ thấp.
Liên hệ

Hãng sx: Horiba - Nhật

- Năm 2016, HORIBA vừa cho ra mắt thiết bị phân tích cỡ hạt tán xạ laser nhỏ gọn mới. Thiết bị này có tính năng vượt trội trong các ứng dụng như bùn, khoáng và hóa chất làm giấy. Thiết bị LA-350 có kích thước nhỏ (297 mm x 420 mm) và dải kích thước rộng hơn (0.1-1000 µm). - Thiết bị Phân tích kích thước hạt tán xạ laser LA-350 là bước cải tiến tiếp theo về hiệu năng, giá cả và kích thước. Thiết bị mới này có thiết kế nhỏ gọn, thông minh và chính xác, chất lượng cao đảm bảo vận hành tiện lợi và tin cậy, cho kết quả chính xác với dải kích thước rộng hơn.
Liên hệ