Hệ thống lò phản ứng để bàn μBenchCAT

Hệ thống lò phản ứng để bàn μBenchCAT

  • 257
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Hệ thống lò phản ứng bán tiêu chuẩn, hoàn toàn có thể cấu hình: cổng khí, nhiệt độ và áp suất

● Hỗ trợ tối đa 6 đường cấp khí và 2 đường cấp chất lỏng

● Lên đến 1200°C và 100 bar (có thể tùy chỉnh cho nhiệt độ cao hơn)

Introduction

The μBenchCAT by Advanced Measurement Instruments (AMI) is a fully integrated, benchtop reactor system designed for comprehensive catalytic studies. Engineered for both gas-phase and liquid-phase reactions, it combines all essential components into a compact, automated platform—ideal for academic, industrial, and R&D environments.

With a variety of configurable options, the μBenchCAT offers exceptional flexibility, making it suitable for a wide range of applications, from catalyst screening and reaction kinetics to long-term stability testing and performance evaluation under real-world conditions.

Features

Maximum Operating Temperature: up to 1200°C, depending on reactor material

Maximum Operating Pressure: up to 100bar

Gas Feed Capability: Up to 6 independently controlled gas feeds

Liquid Feed Options: Configurable for 0, 1, or 2 liquid feeds

Reactor Materials: Available in stainless steel, quartz, or Incoloy to suit a wide range of chemical and thermal environments

Wetted Materials: Durable and chemically resistant components including Stainless Steel, PEEK, Kalrez, Viton, Incoloy, and Quartz

Isothermal Oven: Houses key process components in a uniformly heated environment, minimizing thermal gradients

Multi-Station Capability: Optional Dual μBenchCAT configuration allows for two stations to operate in parallel or series, enabling simultaneous or sequential experiments for enhanced productivity

Full Automation: Controlled through a LabVIEW-based interface for precise operation of temperatures, flows, valve sequences, and reactions

Redundant Safety Systems: Multiple layers of protection, including temperature safety switches, pressure relief valves, positive shut-off valves, firmware-level alarms, and software-based user alarms, ensuring safe and reliable operation

Connection to External Detectors

The μBenchCAT provides seamless integration with external analytical instruments. The product effluent can be routed to a gas chromatograph (GC) or other detectors via an optional sampling valve, available in heated or unheated configurations. This capability enables real-time product analysis and greater experimental insight.

Built-In Safety Systems

Every μBenchCAT is designed with a robust suite of hardware, firmware, and software-level safety features to ensure safe operation under demanding experimental conditions:

• Check valves in all gas and liquid feed lines prevent backflow and cross-contamination.
• Software-coded alarms continuously monitor temperatures and pressures. These alarms are configured by AMI based on system safety limits.
•User-defined alarm matrix allows operators to set custom upper and lower limits for key process parameters and define actions if thresholds are exceeded.

Built-In Safety Systems (continued)

• Hardware over-temperature safety switch protects the furnace from overheating.
• Firmware-level alarms safeguard all heating elements.
• Preset pressure relief valves prevent system over-pressurization.
• Front-mounted power switch provides immediate power cutoff in case of an emergency.
• Double fusing is included in all 220 VAC process equipment for added electrical protection.

These layered safety features ensure that the μBenchCAT can be operated confidently in both routine and advanced catalytic studies.

Software

The μBenchCAT is fully automated to ensure ease of operation, process reliability, and repeatability. Designed for unattended operation, it allows users to configure experiments with minimal manual intervention. The operator simply inputs a sequence of process parameters and control steps, schedules a start time, and the system handles the rest.

All key functions—including valve positions, flow rates, temperatures, pressures, and product sampling—are automatically controlled by the system’s operating software. Data readback is performed at a user-defined sampling rate, and all data are saved in a text-delimited format for easy import into external software platforms for further analysis or reporting.

Control and data acquisition are managed through a dedicated LabVIEW-based application, developed specifically for the μBenchCAT. This software provides intuitive control logic, real-time visualization of system status, and complete experiment tracking, making the μBenchCAT a powerful tool for both routine and advanced catalytic research.

The μBenchCAT software includes three distinct user access levels, allowing controlled operation and protection of critical system settings:

• Locked-Out Mode: This mode is intended for security or safety scenarios where system access must be fully restricted. In this mode, no control actions or changes can be made until authorized login credentials are provided.
• Operator Mode: Designed for routine users, this mode allows access to day-to-day functions such as loading saved procedures, starting/stopping experiments, adjusting basic run parameters, and viewing real-time data. Critical system configurations and calibration settings remain protected.
• Supervisor Mode: This mode provides full access to all system settings, including calibration routines, gas configurations, user management, method creation/editing, and advanced diagnostics. It is intended for experienced users responsible for system setup, maintenance, and high-level customization

AMI Instruments µBenchCAT
Software Screen

Applications

The μBenchCAT is engineered for high-performance catalytic testing in both gas- and liquid- phase environments. All core components are integrated into a compact, bench-top system, delivering precision, flexibility, and ease of use.

Reactor Feed System

The standard configuration supports up to 6 gas feeds and 2 liquid feeds. Each gas line includes a filter, electronic mass flow controller (MFC), check valve, and positive shut-off valve. The range and gas calibration of each MFC are specified by the customer to meet application requirements. Liquids are delivered via high-precision HPLC pumps (or liquid flow controllers), ensuring accurate and stable flow control.

Heated Isothermal Oven

An isothermal oven, operating up to 200°C, houses most process components to maintain a uniform thermal environment. This design minimizes condensation and ensures thermal stability throughout the system. Components located in the oven include:
• Integral gas preheater and liquid preheater/vaporizer, operable up to 300°C
• Feed mixer for combining gas and vapor streams
• Reactor by-pass valves for process flexibility
• Reactor furnace with control and safety thermocouples
• Reactor, equipped with an internal sample thermocouple for accurate temperature measurement

Condenser

A tube-in-tube condenser, located downstream of the reactor and outside the oven, ensures effective removal of condensable components. A thermocouple monitors the coolant return temperature, helping maintain thermal consistency and system stability.

Gas/Liquid Separator

Positioned after the condenser, the gas/liquid separator ensures efficient phase separation. Standard configuration includes high- and low-level switches to activate an automatic drain valve. An optional capacitance liquid level sensor is also available, offering continuous, precise liquid level monitoring for advanced level control and long-duration automation.

Pressure Control

Reactor exit pressure is measured via a dedicated pressure transducer. A high-turndown pressure control valve is used to build and regulate system pressure, enabling steady-state operation under pressurized conditions across a wide pressure range.

Product Sampling Valve (Optional)

An optional product sampling valve can route reactor effluent directly to an external analytical device, such as a gas chromatograph or mass spectrometer, enabling real-time product analysis and enhanced experimental insight.

BUILD A µBENCHCAT

 

Category Option Code
A. Number of Gases 0 G0
1 G1
2 G2
3 G3
4 G4
5 G5
6 G6
B. Number of Liquids 0 L0
1 L1
2 L2
C. Pressure / Temperature ATM / 1200°C 0
50 bar / 650°C 50
100 bar / 650°C 100
100 bar / 800°C 1008
D. Reactor OD 0.25 in 250
0.375 in 375
0.5 in 500
0.75 in 750
E. Reactor Material Quartz Q
316 Stainless Steel S
Inconel I
F. Gas / Liquid Separator No 00
One Stage 01
Two Stage 02
Three Stage 03
G. GC Sampling Line None 00
Unheated After Pressure Reduction 01
Heated slip-stream 02

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: ZonGon - Trung Quốc

Nồi hấp tiệt trùng cỡ nhỏ được sử dụng rộng rãi trong phòng thí nghiệm nghiên cứu sản phẩm mới của nhà máy, thí nghiệm tiệt trùng, viện nghiên cứu đại học...
Liên hệ

Hãng sx: ACA Systems - Phần Lan

ACA RoQ là thiết bị di động và dễ sử dụng để đo độ cứng của từng cuộn giấy, màng nhựa. Thiết bị này lý tưởng cho cả cuộn giấy nguyên liệu, màng film nhựa trước khi cuộn và cuộn giấy thành phẩm.
Liên hệ

Hãng sx: Wisdom - Trung Quốc

- Kiểm tra hoạt độ nước cùng lúc 5 kênh. - Có thể điều khiển bằng phần mềm, hiển thị dữ liệu theo thời gian thực, ghi lại quá trình kiểm tra dữ liệu, kết quả và đồ họa, đáp ứng nhu cầu phân tích và nghiên cứu sâu hơn của bạn; - Sử dụng cảm biến hàng đầu thế giới, kết quả chính xác hơn; - Phương pháp tính toán công nghệ cao, cho kết quả nhanh nhất trong 3 phút, thời gian kiểm tra điển hình là 5 phút, không cần chờ cân lâu; - Máy đo hoạt độ nước để bàn AwLab là trợ thủ đáng tin cậy cho việc kiểm tra hoạt độ nước của bạn.
Liên hệ

Hãng sx: Châu Âu

Máy kiểm tra độ hồi ẩm BRANCA 70S là máy kiểm tra sấy khô trong lò được sử dụng để đo hàm lượng ẩm và độ hồi ẩm của sợi dệt Các tiêu chuẩn phù hợp : IWTO 33, IWTO34, UNI 2060, UNI 9213-1, UNI 9213-2, UNI 9213-3, UNI 9213-4, UNI 9213-5, UNI 9213-6, ISO 6741-1, ISO 6741-2, ISO 6741-4, ASTM D1576-01, ASTM D2495
Liên hệ

Hãng sx: Gester - Trung Quốc

Giới thiệu thiết bị kiểm tra độ mài mòn và xù lông vải Gester GT-C13B Thiết bị kiểm tra độ mài mòn và xù lông vải được sử dụng để xác định khả năng chống mài mòn và đóng cọc của tất cả các loại của các cấu trúc dệt may. Các mẫu được cọ xát với chất mài mòn đã biết ở áp suất thấp và liên tục thay đổi hướng và mức độ mài mòn hoặc vón cục được so sánh với các thông số tiêu chuẩn.
Liên hệ

Hãng sx: Gester - Trung Quốc

Máy kiểm tra độ xé Elmendorf này được thiết kế để kiểm tra độ bền xé của vải dệt, vải không dệt, giấy, bìa cứng, màng mỏng, băng thông gió, vật liệu tấm kim loại, v.v.
Liên hệ

Hãng sx: OpTest - Canada

FQA đo nhanh và chính xác chiều dài, chiều rộng, độ cong, % độ mịn số và độ xoắn của sợi trong các mẫu bột giấy pha loãng. Có sẵn phần mềm tùy chọn để đo độ thô trung bình của sợi theo ISO 23713, Độ dày thành sợi, hỗn hợp gỗ cứng/gỗ mềm, Mức độ xơ hóa sợi bên ngoài, phân tích các mảnh vụn và phân tích các thành phần của mạch. Tế bào dòng chảy được cấp bằng sáng chế chống tắc nghẽn hoặc bám bẩn và định hướng sợi để phân tích hình ảnh chính xác. FQA đáp ứng hoặc vượt quá thông số kỹ thuật của Phương pháp thử nghiệm Tappi T271, PAPTAC B.4 và ISO 16065-1 và -2. Các phụ kiện bao gồm 6 Beaker Carousel và phần mềm OpTiBlend.
Liên hệ

Hãng sx: ATAGO - Nhật Bản

Khúc xạ kế điện tử để bàn Atago model RX-5000α-Bev đo chỉ số khúc xạ tự động, Brix hoặc nồng độ của chất lỏng khác nhau một cách chính xác và nhanh chóng. Máy dùng trong ngành nước giải khát, thực phẩm, sản xuất đường, hóa dầu, mỹ phẩm, dược phẩm. Lăng kính của RX-5000α-Bev được thiết kế tương đối phẳng, dễ lau chùi, thích hợp sử dụng trong ngành nước giải khát.
Liên hệ

Hãng sx: Lumex Instruments - Canada

- Phân tích nhanh các chỉ tiêu protein, độ ẩm, gluten.. trong ngô, gạo hạt chứa dầu, sữa và các sản phẩm từ sữa mà không cần chuẩn bị mẫu. - Dùng để định lượng định tính các chất trong các lĩnh vực môi trường, thực phẩm, nông nghiệp, thức ăn chăn nuôi, sữa, hóa học, dược và hình sự, sinh học, giáo dục, điện tử, vật liệu…
Liên hệ

Hãng sx: FBF- Italy

Cấp đồng hóa: 2 cấp Công suất đồng hóa: 50 lít / giờ Độ nhớt tại nhiệt độ vận hành: < 200 cPs Phần tử có kích thước hạt lớn nhất: < 500 micron Điều kiện vận hành: trong môi trường vệ sinh Nạp liệu: loại trọng lực, qua phễu Áp suất đồng hóa 1 cấp: 0 – 600 bar (0 – 60 MPa) Áp suất đồng hóa 2 cấp: 0 – 150 bar (0 – 15 MPa)
Liên hệ