STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

  • 307
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Nhiều loại đầu dò tia X đếm photon đơn.

● Bức xạ Kα1 tinh khiết sử dụng nguồn Co, Cu, Mo và Ag.

● Chế độ truyền/Debye-Scherrer hoặc Bragg-Brentano.

Introduction

The well-known, high-precision STOE STADI P two circle goniometer is the basis of STOE’s powder diffraction building block system (read more about it here). Vertically or horizontally mounted, the STADI P can be built in Transmission/Debye-Scherrer or Bragg-Brentano geometry. Moreover, two STADI P goniometers, either in the same or different configurations, can be mounted in the same cabinet resulting in two completely independent instruments. However, the two goniometers can also share one source.

  • Various single-photon-counting X-ray detectors
  • Pure Kα1 radiation using Co, Cu, Mo and Ag sources
  • The ultimate platform for laboratory PDF calculations using Ag Kα1 data
  • Transmission/Debye-Scherrer or Bragg-Brentano mode
  • Ideally suited for the analysis of air/moisture-sensitive and microsamples
  • A range of high- and low-temperature attachments available
  • ADVANTAGES OF TRANSMISSION-/ DEBYE-SCHERRER GEOMETRY

  • Same sample volume in the beam over the full 2θ scale
  • Reliable intensities with no necessity for further mathematical corrections
  • No line broadening for weak absorbers
  • No height displacement
  • Real micro-sampling possible
  • Lesser effects of preferred orientation

Specifications

stadip sandwich
 
2θ range 0° up to 140° 2θ
Goniometer 2 circles
Radius of measuring circle 260 mm
Radius of focusing circle 130 mm
X-ray sources Sealed Tubes: Co, Cu, Mo, Ag
Optics Primary monochromator
Software WinXPOW package
Dimensions (including system cabinet, max.) 1800 x 880 x 2050 mm
Weight (complete system) 780 – 940 kg
Detectors Silicon strip detector MYTHEN2 R 1K/2K/3K/4K
Accessories
  • High- and low-temperature attachments for reflection and capillary samples
  • Reaction chamber for capillary samples
  • Various sample stages
  • Various sample changers
Powder STADI P DSC 7323 RZ e1686834392423
The STADI P can be set up by itself or as a dual setup with two different geometries on the independent goniometers.
STADIP 1 e1681798921908
The horizontal STADI P set up with a capillary sample holder.
STADIP 2
The horizontal STADI P set up with STOE's transmission sample holder.
Mythen 3K e1686833321953
For ultra fast measurements of e.g. unstable samples STOE offers an installation with up to four MYTHEN detectors. With four MYTHEN detectors a single exposure will cover 0 - 73° in 2θ. (See the respective AppNote)

ADAMAnT

When an X-ray tube ages, it is possible that its take off angle changes, resulting in a 2 Theta shift of the reflex positions on the detector. To reverse the impact of this take off angle change, the monochromator and sample position have to be adapted through a Beam Optimization.
The STOE STADI P Beam Optimization has been a well-established tool of the WinXPOW software for a very long time. It automatically sets the Johann type monochromator to the maximum intensity of the Kα1-radiation of a sealed tube’s line focus by the help of a certified standard material – but the alignment of the goniometer axis into the beam path has – so far – still to be done manually with a luminance screen.
From now on, the unique ADAMAnT tool aligns monochromator and goniometer automated to the Kα1-radiation, making any contact with the open beam or its air scattered radiation no longer necessary, no matter whether it is only the exchange of a worn-out tube by a new one with the same anode material or whether the radiation should be swapped to a different one.
The ADAMAnT is available for all typical anode materials (Co, Cu, Mo, Ag) but currently only for horizontal setups, with plans for future availability in vertical configurations and conveniently, can be integrated into existing horizontal STADI P diffractometers.

StadiP2 reveal new 1536x1536
Rendering of a horizontal STADI P including the hardware for the ADAMAnT

STADi P for pdf data collection

As the demand for materials with lower degrees of order continues to rise, the significance of Pair Distribution Function (PDF) measurements is growing steadily. To measure best possible data for PDF interpretation, the STADI P can be installed with Ag Kα1 radiation and expanded with a PDF collimator, a MYTHEN2 4K detector and optionally air scattering shields, without any loss in diffraction data quality.

PDF comparison Zobel e1681221508789
This direct comparison of PDF data measured on the ionic liquid hmimPF6 shows how excellent our instrument performs versus a synchrotron. Plot from: doi.org/10.1063/1.5093714
STOE Transmission 054 bearb e1686834533942
PDF data is preferably collected in Debye-Scherrer geometry, which is beneficial for air sensitive samples.
PDF1 e1684828024312
With the MYTHEN2 4K detector in one-step mode you can measure up to 144° 2θ (2x 27° simultaneously, see the respective AppNote) in shortest time.
multimythenPDF e1684828157149
Shields can optionally be set on the detectors to reduce additional effects of air scattering
STOE Transmission 070 e1686834558935
For PDF measurements we offer a special collimator to reduce addittional background signal at high angles.

Software & Accessories

WinXPOW, is a uniquely designed powder diffraction software developed exclusively by our skilled team at STOE. It is meticulously crafted to perfectly work with our instruments, ensuring seamless compatibility and optimal performance. In addition to controlling the instruments, WinXPOW provides a comprehensive range of cutting-edge features. These include data reduction, profile fitting, pattern indexing, and spacegroup determination. Moreover, it boasts an array of powerful functionalities, such as advanced 2D and 3D graphics, among numerous other capabilities.

 

We provide a wide range of accessories to customize your sample environment according to your specific requirements. Our products encompass high temperature and reaction chambers, sample changers, dedicated battery cell holders, and various other accessories to enhance your experimentation capabilities.

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: COPLEY - Anh Quốc

Mô tả : Tuân thủ Dược điển: Theo tiêu chuẩn có trong dược điển châu âu chương 2.9.8 và dược điển Mỹ chương 1217 Đường kính viên thuốc tối đa: 30 mm Khoảng đo: 0 - 500N (+/- 0.1N) Kích thước: 82 x 380 x 90 mm
Liên hệ

Hãng sx: Bayerteq - Đức

Máy thử nghiệm Bayerteq RCP S4 ISO 13 477, Kiểm tra áp suất và cơ học Máy thử nghiệm Lan truyền vết Nứt Nhanh Bayerteq mang lại độ chính xác vượt trội khi thử nghiệm ống nhựa.
Liên hệ

Hãng sx: Bayerteq - Đức

**ASTM D 1598, ASTM D 1599, EN 12 293, ISO 1167, Kiểm tra áp suất và cơ học** Dòng HPM XV dành cho thể tích lớn Dòng HPM XV dành cho thử nghiệm áp suất nội bộ đối với các hệ thống ống lớn.
Liên hệ

Hãng sx: Bayerteq - Đức

**ASTM D 1598, ASTM D 1599, EN 12 293, ISO 1167, Kiểm tra áp suất và cơ học** Dòng HPM XP dành cho Áp suất cao Dòng HPM XP dành cho thử nghiệm áp suất nội bộ ở mức áp suất cao.
Liên hệ

Hãng sx: Bayerteq - Đức

Tủ áp suất Bayerteq HPM 2B- Series Thiết bị kiểm tra áp suất thế hệ mới cho thử nghiệm áp suất nội bộ ASTM D 1598, ASTM D 1599, ASTM D 1603, ISO 1167, Kiểm tra áp suất và cơ học
Liên hệ

Hãng sx: Bayerteq - Đức

Việc di chuyển mẫu lên xuống trong buồng có thể thực hiện thủ công hoặc tự động hóa, tùy thuộc vào mẫu máy. Độ phân giải dịch chuyển: 1mm Máy thử va đập Bayerteq đi kèm với các tính năng an toàn, ngừng hoạt động của máy khi cửa đang mở và được trang bị hệ thống điều khiển thả búa bằng hai tay. Thiết bị được thiết kế theo tiêu chuẩn 89/392 EEC.
Liên hệ

Hãng sx: Bayerteq - Đức

Bayerteq đã phát triển một máy thử va đập với trọng lượng rơi mới, không chỉ tuân thủ các tiêu chuẩn ISO 3127, EN 744, EN 1411 và ASTM D 2444, mà còn tuân thủ tiêu chuẩn UL651. Dòng BT FWV UL cung cấp khả năng độc đáo để thực hiện các thử nghiệm va đập với trọng lượng rơi theo tất cả các tiêu chuẩn ISO, ASTM D và UL651, đảm bảo rằng dòng FWV UL có thể xử lý được các trọng lượng rơi đặc biệt của UL, có trọng lượng lên đến 34 kg.
Liên hệ

Hãng sx: Bayerteq - Đức

Máy thử va đập với trọng lượng rơi Bayerteq được phát triển để kiểm tra khả năng chống va đập ngoại vi theo cả phương pháp từng bậc và phương pháp liên tục, theo các tiêu chuẩn ISO 3127, EN 744, EN 1411, ASTM D 2444 và các tiêu chuẩn tương đương. Với máy thử va đập này, các trọng lượng rơi được nâng lên đỉnh tháp bằng hệ thống chân không thông qua một máy bơm, giúp hút trọng lượng rơi lên đỉnh tháp một cách nhanh chóng. Dòng BT FWS có 3 kích thước khác nhau: lên đến DN 630 mm, lên đến DN 1400 mm và lên đến DN 2000 mm. Chiều cao rơi có thể được cài đặt từ 50 mm đến 2000 mm, với hệ thống chống nẩy giúp ngăn trọng lượng rơi bật lại mẫu ống. Chiều cao rơi có thể được hiệu chuẩn tự động. Theo yêu cầu, chúng tôi cũng có thể cung cấp chiều cao rơi 3000 mm và 4000 mm.
Liên hệ

Hãng sx: Bayerteq - Đức

Máy kiểm tra va đập con lắc là một thiết bị được sử dụng để thực hiện thử nghiệm va đập trên các vật liệu nhựa nhiệt dẻo nhằm xác định đặc tính giòn của chúng dưới tác động của ứng suất xác định. **Đặc điểm**: 1) Màn hình cảm ứng, các tham số thử nghiệm có thể được thiết lập qua màn hình cảm ứng; với chức năng hiệu chuẩn tự động năng lượng mất mát. Độ chính xác cao, ổn định tuyệt vời và dễ vận hành giúp máy đạt chứng nhận CE và có thể được bán trên toàn thế giới. 2) Có thể cắm USB để chuyển kết quả thử nghiệm sang máy tính. 3) Tính toán tự động năng lượng va đập và sức mạnh va đập, kết quả thử nghiệm có thể hiển thị và in ra. 4) Thiết bị thu thập góc quang điện đảm bảo độ chính xác của kết quả thử nghiệm, góc hiện tại của con lắc có thể được hiển thị.
Liên hệ

Hãng sx: Bayerteq - Đức

Máy kiểm tra chu kỳ nhiệt được thiết kế để xác định khả năng chịu đựng và độ ổn định của hệ thống ống nhựa nhiệt dẻo khi phải chịu tác động của các chu kỳ nhiệt độ theo thời gian quy định dưới tải trọng áp suất nội bộ xác định. Thiết bị này áp dụng cho các hệ thống ống dẫn dự kiến sử dụng để dẫn nước nóng và lạnh có áp suất.
Liên hệ