STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

  • 229
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Nhiều loại đầu dò tia X đếm photon đơn.

● Bức xạ Kα1 tinh khiết sử dụng nguồn Co, Cu, Mo và Ag.

● Chế độ truyền/Debye-Scherrer hoặc Bragg-Brentano.

Introduction

The well-known, high-precision STOE STADI P two circle goniometer is the basis of STOE’s powder diffraction building block system (read more about it here). Vertically or horizontally mounted, the STADI P can be built in Transmission/Debye-Scherrer or Bragg-Brentano geometry. Moreover, two STADI P goniometers, either in the same or different configurations, can be mounted in the same cabinet resulting in two completely independent instruments. However, the two goniometers can also share one source.

  • Various single-photon-counting X-ray detectors
  • Pure Kα1 radiation using Co, Cu, Mo and Ag sources
  • The ultimate platform for laboratory PDF calculations using Ag Kα1 data
  • Transmission/Debye-Scherrer or Bragg-Brentano mode
  • Ideally suited for the analysis of air/moisture-sensitive and microsamples
  • A range of high- and low-temperature attachments available
  • ADVANTAGES OF TRANSMISSION-/ DEBYE-SCHERRER GEOMETRY

  • Same sample volume in the beam over the full 2θ scale
  • Reliable intensities with no necessity for further mathematical corrections
  • No line broadening for weak absorbers
  • No height displacement
  • Real micro-sampling possible
  • Lesser effects of preferred orientation

Specifications

stadip sandwich
 
2θ range 0° up to 140° 2θ
Goniometer 2 circles
Radius of measuring circle 260 mm
Radius of focusing circle 130 mm
X-ray sources Sealed Tubes: Co, Cu, Mo, Ag
Optics Primary monochromator
Software WinXPOW package
Dimensions (including system cabinet, max.) 1800 x 880 x 2050 mm
Weight (complete system) 780 – 940 kg
Detectors Silicon strip detector MYTHEN2 R 1K/2K/3K/4K
Accessories
  • High- and low-temperature attachments for reflection and capillary samples
  • Reaction chamber for capillary samples
  • Various sample stages
  • Various sample changers
Powder STADI P DSC 7323 RZ e1686834392423
The STADI P can be set up by itself or as a dual setup with two different geometries on the independent goniometers.
STADIP 1 e1681798921908
The horizontal STADI P set up with a capillary sample holder.
STADIP 2
The horizontal STADI P set up with STOE's transmission sample holder.
Mythen 3K e1686833321953
For ultra fast measurements of e.g. unstable samples STOE offers an installation with up to four MYTHEN detectors. With four MYTHEN detectors a single exposure will cover 0 - 73° in 2θ. (See the respective AppNote)

ADAMAnT

When an X-ray tube ages, it is possible that its take off angle changes, resulting in a 2 Theta shift of the reflex positions on the detector. To reverse the impact of this take off angle change, the monochromator and sample position have to be adapted through a Beam Optimization.
The STOE STADI P Beam Optimization has been a well-established tool of the WinXPOW software for a very long time. It automatically sets the Johann type monochromator to the maximum intensity of the Kα1-radiation of a sealed tube’s line focus by the help of a certified standard material – but the alignment of the goniometer axis into the beam path has – so far – still to be done manually with a luminance screen.
From now on, the unique ADAMAnT tool aligns monochromator and goniometer automated to the Kα1-radiation, making any contact with the open beam or its air scattered radiation no longer necessary, no matter whether it is only the exchange of a worn-out tube by a new one with the same anode material or whether the radiation should be swapped to a different one.
The ADAMAnT is available for all typical anode materials (Co, Cu, Mo, Ag) but currently only for horizontal setups, with plans for future availability in vertical configurations and conveniently, can be integrated into existing horizontal STADI P diffractometers.

StadiP2 reveal new 1536x1536
Rendering of a horizontal STADI P including the hardware for the ADAMAnT

STADi P for pdf data collection

As the demand for materials with lower degrees of order continues to rise, the significance of Pair Distribution Function (PDF) measurements is growing steadily. To measure best possible data for PDF interpretation, the STADI P can be installed with Ag Kα1 radiation and expanded with a PDF collimator, a MYTHEN2 4K detector and optionally air scattering shields, without any loss in diffraction data quality.

PDF comparison Zobel e1681221508789
This direct comparison of PDF data measured on the ionic liquid hmimPF6 shows how excellent our instrument performs versus a synchrotron. Plot from: doi.org/10.1063/1.5093714
STOE Transmission 054 bearb e1686834533942
PDF data is preferably collected in Debye-Scherrer geometry, which is beneficial for air sensitive samples.
PDF1 e1684828024312
With the MYTHEN2 4K detector in one-step mode you can measure up to 144° 2θ (2x 27° simultaneously, see the respective AppNote) in shortest time.
multimythenPDF e1684828157149
Shields can optionally be set on the detectors to reduce additional effects of air scattering
STOE Transmission 070 e1686834558935
For PDF measurements we offer a special collimator to reduce addittional background signal at high angles.

Software & Accessories

WinXPOW, is a uniquely designed powder diffraction software developed exclusively by our skilled team at STOE. It is meticulously crafted to perfectly work with our instruments, ensuring seamless compatibility and optimal performance. In addition to controlling the instruments, WinXPOW provides a comprehensive range of cutting-edge features. These include data reduction, profile fitting, pattern indexing, and spacegroup determination. Moreover, it boasts an array of powerful functionalities, such as advanced 2D and 3D graphics, among numerous other capabilities.

 

We provide a wide range of accessories to customize your sample environment according to your specific requirements. Our products encompass high temperature and reaction chambers, sample changers, dedicated battery cell holders, and various other accessories to enhance your experimentation capabilities.

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: Pnshar - Trung Quốc

Máy cắt giấy PN-TPC15 được thiết kế để cắt mẫu cho máy thử độ kéo PN-TT300F, cũng có thể được sử dụng để lấy mẫu cho máy thử độ bền ngắn PN-SCTF và máy thử độ bền gấp PN-NZ135F, v.v. Đây là một thiết bị thử nghiệm lý tưởng trong ngành sản xuất giấy, bao bì và các ngành công nghiệp khác của các cơ quan giám sát chất lượng, kiểm tra và hỗ trợ.
Liên hệ

Hãng sx: No brand

Tiêu chuẩn: GB / T 6544, GB / T 6546, GB / T 6548, GB / T 2679,17
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy cắt mẫu FCT loại PN-FCC32/64/100 được thiết kế để cắt mẫu cho bài kiểm tra ép phẳng (Flat Crush Test - FCT) của bìa carton sóng, yêu cầu mẫu cắt đặc biệt.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

- Máy cắt mẫu tròn có thể lấy mẫu tròn. Sau đó, thiết bị lấy mẫu có thể cắt kích thước mẫu nhanh chóng và chính xác để lấy mẫu Grammage - Ứng dụng: cắt mẫu tiêu chuẩn dùng đo định lượng giấy
Liên hệ

Hãng sx: Pnshar - Trung Quốc

PN-DQTF Máy kiểm tra sự rụng bột giấy khăn giấy là thiết bị kiểm tra tỷ lệ rụng bột giấy được phát triển theo tiêu chuẩn quốc gia GB/T 20810-2018, phù hợp với các sản phẩm như giấy vệ sinh cuộn, giấy vệ sinh phẳng, giấy vệ sinh jumbo và các loại sản phẩm khác.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy nấu bột giấy dùng thử nghiệm này được thiết kế mô phỏng theo nguyên lý hoạt động của nồi hơi, với phần thân nồi có chuyển động vòng cung, giúp bột giấy được trộn đều. Thiết bị này phù hợp với các phòng thí nghiệm sản xuất giấy để nấu các loại nguyên liệu sợi bằng axit hoặc kiềm. Tùy theo yêu cầu của quy trình, thiết bị có thể điều chỉnh kích thước để phục vụ cho việc phát triển quy trình nấu trong sản xuất. Ngoài ra, thiết bị còn có thể sử dụng để nấu các nguyên liệu lỏng khác có áp suất không quá 8 kg/cm². Bên cạnh chức năng nấu, máy tiêu hóa này còn có thể được sử dụng cho các thiết bị khác trong phòng thí nghiệm sử dụng hơi nóng.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

PN-PT12F Máy đo độ dày giấy tissue là thiết bị đo độ dày giấy tissue được thiết kế và phát triển theo tiêu chuẩn quốc gia GB/T24328.2 và ISO 12625.3, phù hợp với giấy tissue và các sản phẩm của nó. Sản phẩm này là một thiết bị tích hợp cơ điện. Nó áp dụng các khái niệm thiết kế cơ khí hiện đại và nguyên lý thiết kế công thái học. Đây là một thiết bị đo độ dày chính xác cao, có thiết kế mới mẻ, dễ sử dụng, hiệu suất vượt trội và hình thức trang nhã. Sử dụng cảm biến dịch chuyển chính xác cao, sản phẩm có các chức năng kiểm tra, chuyển đổi, hiển thị, lưu trữ, in ấn và xử lý dữ liệu. Đây là thiết bị thử nghiệm lý tưởng cho các ngành công nghiệp và các phòng ban như sản xuất giấy, bao bì, nghiên cứu khoa học và giám sát chất lượng sản phẩm.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy nghiền Valley 23 lít này được chế tạo theo các tiêu chuẩn ISO và TAPPI. Đây là thiết bị phòng thí nghiệm sản xuất giấy dùng để nghiền bột giấy, một thiết bị cần thiết cho việc nghiên cứu quá trình chế biến bột giấy và giấy. Nó được sử dụng để cắt/đập/nặn/chia nhỏ các vật liệu sợi bằng lực cơ học của dao quay và dao đáy, nhằm đáp ứng yêu cầu chất lượng của việc sản xuất giấy hoặc các sản phẩm giấy khác.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

PN-MF Medium Fluter được thiết kế để tạo nếp gấp cho mẫu giấy bằng cách sử dụng hai trục tạo nếp. Sau đó, các mẫu được kiểm tra trong máy kiểm tra nén để đánh giá CMT (Thử nghiệm Chất lượng Giấy Lót) và CCT (Thử nghiệm Nén Giấy Sóng) theo các tiêu chuẩn: QB/T 1061 và ISO7263.
Liên hệ

Hãng sx: Emco - Đức

Máy kiểm tra giãn nở ướt tự động theo phương pháp Fenchel, Mütek CD và MD trong một thiết bị Máy kiểm tra giãn nở ướt emco NDT mới cho giấy sử dụng nguyên lý đo động để xác định đường giãn nở ướt. Việc kiểm tra giãn nở ướt của giấy là quan trọng để đánh giá hành vi vật liệu trong quá trình sản xuất cũng như trong ứng dụng, chỉ khi sử dụng phương pháp đo động. Việc đo giãn nở của mẫu giấy có thể được thực hiện trong các dung dịch thử nghiệm khác nhau. Kết hợp với việc ngâm và thời gian giãn nở, quá trình ứng dụng có thể được mô phỏng tối ưu. Giãn nở của giấy do chất lỏng có nghĩa là sự phình ra của sợi giấy do sự hấp thụ chất lỏng. Do đó, sợi giấy sẽ giãn nở ít hơn theo phương máy (MD) so với phương chéo (CD). Kết quả tương đương thu được từ việc đo giãn nở ướt trong điều kiện khí hậu chuẩn (23 °C, 50 % độ ẩm) và trọng lượng đối trọng xác định (Fenchel, Mütek CD, Mütek MD).
Liên hệ