STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

  • 206
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Nhiều loại đầu dò tia X đếm photon đơn.

● Bức xạ Kα1 tinh khiết sử dụng nguồn Co, Cu, Mo và Ag.

● Chế độ truyền/Debye-Scherrer hoặc Bragg-Brentano.

Introduction

The well-known, high-precision STOE STADI P two circle goniometer is the basis of STOE’s powder diffraction building block system (read more about it here). Vertically or horizontally mounted, the STADI P can be built in Transmission/Debye-Scherrer or Bragg-Brentano geometry. Moreover, two STADI P goniometers, either in the same or different configurations, can be mounted in the same cabinet resulting in two completely independent instruments. However, the two goniometers can also share one source.

  • Various single-photon-counting X-ray detectors
  • Pure Kα1 radiation using Co, Cu, Mo and Ag sources
  • The ultimate platform for laboratory PDF calculations using Ag Kα1 data
  • Transmission/Debye-Scherrer or Bragg-Brentano mode
  • Ideally suited for the analysis of air/moisture-sensitive and microsamples
  • A range of high- and low-temperature attachments available
  • ADVANTAGES OF TRANSMISSION-/ DEBYE-SCHERRER GEOMETRY

  • Same sample volume in the beam over the full 2θ scale
  • Reliable intensities with no necessity for further mathematical corrections
  • No line broadening for weak absorbers
  • No height displacement
  • Real micro-sampling possible
  • Lesser effects of preferred orientation

Specifications

stadip sandwich
 
2θ range 0° up to 140° 2θ
Goniometer 2 circles
Radius of measuring circle 260 mm
Radius of focusing circle 130 mm
X-ray sources Sealed Tubes: Co, Cu, Mo, Ag
Optics Primary monochromator
Software WinXPOW package
Dimensions (including system cabinet, max.) 1800 x 880 x 2050 mm
Weight (complete system) 780 – 940 kg
Detectors Silicon strip detector MYTHEN2 R 1K/2K/3K/4K
Accessories
  • High- and low-temperature attachments for reflection and capillary samples
  • Reaction chamber for capillary samples
  • Various sample stages
  • Various sample changers
Powder STADI P DSC 7323 RZ e1686834392423
The STADI P can be set up by itself or as a dual setup with two different geometries on the independent goniometers.
STADIP 1 e1681798921908
The horizontal STADI P set up with a capillary sample holder.
STADIP 2
The horizontal STADI P set up with STOE's transmission sample holder.
Mythen 3K e1686833321953
For ultra fast measurements of e.g. unstable samples STOE offers an installation with up to four MYTHEN detectors. With four MYTHEN detectors a single exposure will cover 0 - 73° in 2θ. (See the respective AppNote)

ADAMAnT

When an X-ray tube ages, it is possible that its take off angle changes, resulting in a 2 Theta shift of the reflex positions on the detector. To reverse the impact of this take off angle change, the monochromator and sample position have to be adapted through a Beam Optimization.
The STOE STADI P Beam Optimization has been a well-established tool of the WinXPOW software for a very long time. It automatically sets the Johann type monochromator to the maximum intensity of the Kα1-radiation of a sealed tube’s line focus by the help of a certified standard material – but the alignment of the goniometer axis into the beam path has – so far – still to be done manually with a luminance screen.
From now on, the unique ADAMAnT tool aligns monochromator and goniometer automated to the Kα1-radiation, making any contact with the open beam or its air scattered radiation no longer necessary, no matter whether it is only the exchange of a worn-out tube by a new one with the same anode material or whether the radiation should be swapped to a different one.
The ADAMAnT is available for all typical anode materials (Co, Cu, Mo, Ag) but currently only for horizontal setups, with plans for future availability in vertical configurations and conveniently, can be integrated into existing horizontal STADI P diffractometers.

StadiP2 reveal new 1536x1536
Rendering of a horizontal STADI P including the hardware for the ADAMAnT

STADi P for pdf data collection

As the demand for materials with lower degrees of order continues to rise, the significance of Pair Distribution Function (PDF) measurements is growing steadily. To measure best possible data for PDF interpretation, the STADI P can be installed with Ag Kα1 radiation and expanded with a PDF collimator, a MYTHEN2 4K detector and optionally air scattering shields, without any loss in diffraction data quality.

PDF comparison Zobel e1681221508789
This direct comparison of PDF data measured on the ionic liquid hmimPF6 shows how excellent our instrument performs versus a synchrotron. Plot from: doi.org/10.1063/1.5093714
STOE Transmission 054 bearb e1686834533942
PDF data is preferably collected in Debye-Scherrer geometry, which is beneficial for air sensitive samples.
PDF1 e1684828024312
With the MYTHEN2 4K detector in one-step mode you can measure up to 144° 2θ (2x 27° simultaneously, see the respective AppNote) in shortest time.
multimythenPDF e1684828157149
Shields can optionally be set on the detectors to reduce additional effects of air scattering
STOE Transmission 070 e1686834558935
For PDF measurements we offer a special collimator to reduce addittional background signal at high angles.

Software & Accessories

WinXPOW, is a uniquely designed powder diffraction software developed exclusively by our skilled team at STOE. It is meticulously crafted to perfectly work with our instruments, ensuring seamless compatibility and optimal performance. In addition to controlling the instruments, WinXPOW provides a comprehensive range of cutting-edge features. These include data reduction, profile fitting, pattern indexing, and spacegroup determination. Moreover, it boasts an array of powerful functionalities, such as advanced 2D and 3D graphics, among numerous other capabilities.

 

We provide a wide range of accessories to customize your sample environment according to your specific requirements. Our products encompass high temperature and reaction chambers, sample changers, dedicated battery cell holders, and various other accessories to enhance your experimentation capabilities.

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: Biuged Instruments - China

BGD 310 là máy thử cupping tự động. Trên cơ sở của BGD 309, máy này có thể tự động nâng lên với tốc độ 0,2mm/giây theo tiêu chuẩn yêu cầu. Loại bỏ lỗi do nâng bằng tay.
Liên hệ

Hãng sx: Biuged Instruments - China

Máy thử va đập BGD 301 Dupont được thiết kế để kiểm tra độ bền va đập của vật liệu phủ (sau khi phủ). Máy được trang bị 5 đầu đo có đường kính khác nhau và khuôn liên quan, 3 trọng lượng khác nhau. Máy tương thích với ASTM D 2794, JISK 5400, CNS 10756.
Liên hệ

Hãng sx: Biuged Instruments - China

Thiết bị thử độ bền uốn của màng sơn là thiết bị được sử dụng để kiếm tra khả năng bền uốn của sơn trên các bề mặt như kim loại, bê tông, gỗ, nhựa,… qua đó người sử dụng có thể xác định dễ dàng được tính chất của sản phẩm.
Liên hệ

Hãng sx: Biuged Instruments - China

Máy kiểm tra hình nón (kiểm tra nứt/ bong) Biuged BGD 566 có thể áp dụng để xác định khả năng mở rộng của lớp sơn phủ trên các tấm kim loại được kẹp cố định và tạo thành quanh trục hình nón bằng cách quay khung con lăn. Các tấm được kiểm tra để đánh giá khả năng chống nứt và bong ra khỏi nền kim loại của bề mặt được phủ sơn ở điều kiện tiêu chuẩn. Nó tuân thủ tiêu chuẩn ASTM D 522,D1737,BS 3900E11 và ISO 6860.
Liên hệ

Hãng sx: Biuged Instruments - China

-Được thiết kế để đánh giá tính linh hoạt và độ bám dính của lớp phủ hữu cơ trên nền kim loại bằng cách quan sát vết nứt hoặc mất độ bám dính khi tấm thử nghiệm phủ bị uốn cong. Phương pháp này có thể được sử dụng để xác nhận xem sơn, vecni hoặc các sản phẩm liên quan có đáp ứng một thử nghiệm nhất định hay không. yêu cầu trong thử nghiệm đạt / không đạt, hoặc để xác định đường kính uốn tối thiểu mà tại đó vết nứt không xảy ra.
Liên hệ

Hãng sx: Biuged Instruments - China

Sau khi hoàn tất thử nghiệm cắt ngang trên màng phủ, người vận hành phải đánh giá chính xác tỷ lệ phần trăm diện tích bong tróc và sau đó phân loại, phương pháp truyền thống là bằng mắt thường. Vì khó có thể định lượng chính xác diện tích bong tróc bằng mắt thường nên có sự khác biệt chủ quan tương đối lớn trong kết quả hoặc phân loại và dễ gây tranh cãi. Để giải quyết vấn đề này và cải thiện khả năng lặp lại và khả năng tái tạo kết quả thử nghiệm cắt ngang, Biuged đã phát triển một thiết bị có thể tự động xác định diện tích bong tróc. Thiết bị này sử dụng công nghệ xử lý hình ảnh kỹ thuật số máy tính (phân tích tự động trực quan) để chụp ảnh diện tích cắt ngang, sau đó phân tích và tính toán hình ảnh kỹ thuật số, có thể nhanh chóng và dễ dàng thu được kết quả chính xác.
Liên hệ

Hãng sx: Biuged Instruments - China

Tiêu chuẩn ISO 2409-2019 mới nhất đã xác định rõ ràng rằng để có được đường cắt đồng đều và nhất quán, phải sử dụng máy thử độ bám dính tự động nở chéo với ổ đĩa động cơ càng nhiều càng tốt. Máy kiểm tra độ bám dính BGD 535 là một thiết bị tự động. Dụng cụ cắt ngang được thiết kế theo tiêu chuẩn ISO 2409 và ASTM 3359 mới nhất.
Liên hệ

Hãng sx: Biuged Instruments - China

Máy thử độ bám dính kỹ thuật số tự động BGD 500 / S là một thiết bị cầm tay, được sử dụng để đo lực cần thiết để kéo một đường kính thử nghiệm xác định của lớp phủ ra khỏi bề mặt bằng cách sử dụng áp suất thủy lực. Áp suất được hiển thị trên màn hình LCD kỹ thuật số và thể hiện độ bám dính của lớp phủ với chất nền.
Liên hệ

Hãng sx: Biuged Instruments - China

Thiết bị kiểm tra độ bám dính kỹ thuật số BGD 500 là một thiết bị cầm tay, vận hành bằng tay, được sử dụng để đo lực cần thiết để kéo một đường kính thử nghiệm xác định của lớp phủ ra khỏi đế bằng áp suất thủy lực. Áp lực được hiển thị trên màn hình LCD kỹ thuật số và đại diện cho lớp phủ'sức mạnh của của sự bám dính vào bề mặt. Nó đánh giá độ bám dính (cường độ kéo) của lớp phủ bằng cách xác định lực kéo đứt lớn nhất mà nó có thể chịu được trước khi tháo ra. Các điểm phá vỡ, được thể hiện bằng các bề mặt bị nứt, xảy ra dọc theo mặt phẳng yếu nhất trong hệ thống bao gồm các lớp dolly, dính, lớp phủ và chất nền.
Liên hệ

Hãng sx: Biuged Instruments - China

– Dụng cụ kiểm tra độ bám dính màng sơn BGD 502 và BGD 504 của hãng Biuged là thiết bị được sử dụng rộng rãi để đánh giá nhanh độ bám dính của lớp phủ trên sắt, thép, nhôm, gỗ, giấy,…. – Dụng cụ là một tay cầm có gắn một bánh xe có 6 hoặc 11 lưỡi dao cắt với khoảng cách giữa các lưỡi khác nhau có độ chính xác cao. Tuy được sản xuất ở Trung Quốc nhưng dụng cụ kiểm tra độ bám dính màng sơn hãng Biuged phù hợp theo tiêu chuẩn: BS 3900 E6, BS / EN ISO 2409, ASTM D 3359 D 3302 nên quý khách hoàn toàn có thể an tâm về chất lượng sản phẩm cũng như kết quả của việc kiểm tra.
Liên hệ