STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

  • 204
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Nhiều loại đầu dò tia X đếm photon đơn.

● Bức xạ Kα1 tinh khiết sử dụng nguồn Co, Cu, Mo và Ag.

● Chế độ truyền/Debye-Scherrer hoặc Bragg-Brentano.

Introduction

The well-known, high-precision STOE STADI P two circle goniometer is the basis of STOE’s powder diffraction building block system (read more about it here). Vertically or horizontally mounted, the STADI P can be built in Transmission/Debye-Scherrer or Bragg-Brentano geometry. Moreover, two STADI P goniometers, either in the same or different configurations, can be mounted in the same cabinet resulting in two completely independent instruments. However, the two goniometers can also share one source.

  • Various single-photon-counting X-ray detectors
  • Pure Kα1 radiation using Co, Cu, Mo and Ag sources
  • The ultimate platform for laboratory PDF calculations using Ag Kα1 data
  • Transmission/Debye-Scherrer or Bragg-Brentano mode
  • Ideally suited for the analysis of air/moisture-sensitive and microsamples
  • A range of high- and low-temperature attachments available
  • ADVANTAGES OF TRANSMISSION-/ DEBYE-SCHERRER GEOMETRY

  • Same sample volume in the beam over the full 2θ scale
  • Reliable intensities with no necessity for further mathematical corrections
  • No line broadening for weak absorbers
  • No height displacement
  • Real micro-sampling possible
  • Lesser effects of preferred orientation

Specifications

stadip sandwich
 
2θ range 0° up to 140° 2θ
Goniometer 2 circles
Radius of measuring circle 260 mm
Radius of focusing circle 130 mm
X-ray sources Sealed Tubes: Co, Cu, Mo, Ag
Optics Primary monochromator
Software WinXPOW package
Dimensions (including system cabinet, max.) 1800 x 880 x 2050 mm
Weight (complete system) 780 – 940 kg
Detectors Silicon strip detector MYTHEN2 R 1K/2K/3K/4K
Accessories
  • High- and low-temperature attachments for reflection and capillary samples
  • Reaction chamber for capillary samples
  • Various sample stages
  • Various sample changers
Powder STADI P DSC 7323 RZ e1686834392423
The STADI P can be set up by itself or as a dual setup with two different geometries on the independent goniometers.
STADIP 1 e1681798921908
The horizontal STADI P set up with a capillary sample holder.
STADIP 2
The horizontal STADI P set up with STOE's transmission sample holder.
Mythen 3K e1686833321953
For ultra fast measurements of e.g. unstable samples STOE offers an installation with up to four MYTHEN detectors. With four MYTHEN detectors a single exposure will cover 0 - 73° in 2θ. (See the respective AppNote)

ADAMAnT

When an X-ray tube ages, it is possible that its take off angle changes, resulting in a 2 Theta shift of the reflex positions on the detector. To reverse the impact of this take off angle change, the monochromator and sample position have to be adapted through a Beam Optimization.
The STOE STADI P Beam Optimization has been a well-established tool of the WinXPOW software for a very long time. It automatically sets the Johann type monochromator to the maximum intensity of the Kα1-radiation of a sealed tube’s line focus by the help of a certified standard material – but the alignment of the goniometer axis into the beam path has – so far – still to be done manually with a luminance screen.
From now on, the unique ADAMAnT tool aligns monochromator and goniometer automated to the Kα1-radiation, making any contact with the open beam or its air scattered radiation no longer necessary, no matter whether it is only the exchange of a worn-out tube by a new one with the same anode material or whether the radiation should be swapped to a different one.
The ADAMAnT is available for all typical anode materials (Co, Cu, Mo, Ag) but currently only for horizontal setups, with plans for future availability in vertical configurations and conveniently, can be integrated into existing horizontal STADI P diffractometers.

StadiP2 reveal new 1536x1536
Rendering of a horizontal STADI P including the hardware for the ADAMAnT

STADi P for pdf data collection

As the demand for materials with lower degrees of order continues to rise, the significance of Pair Distribution Function (PDF) measurements is growing steadily. To measure best possible data for PDF interpretation, the STADI P can be installed with Ag Kα1 radiation and expanded with a PDF collimator, a MYTHEN2 4K detector and optionally air scattering shields, without any loss in diffraction data quality.

PDF comparison Zobel e1681221508789
This direct comparison of PDF data measured on the ionic liquid hmimPF6 shows how excellent our instrument performs versus a synchrotron. Plot from: doi.org/10.1063/1.5093714
STOE Transmission 054 bearb e1686834533942
PDF data is preferably collected in Debye-Scherrer geometry, which is beneficial for air sensitive samples.
PDF1 e1684828024312
With the MYTHEN2 4K detector in one-step mode you can measure up to 144° 2θ (2x 27° simultaneously, see the respective AppNote) in shortest time.
multimythenPDF e1684828157149
Shields can optionally be set on the detectors to reduce additional effects of air scattering
STOE Transmission 070 e1686834558935
For PDF measurements we offer a special collimator to reduce addittional background signal at high angles.

Software & Accessories

WinXPOW, is a uniquely designed powder diffraction software developed exclusively by our skilled team at STOE. It is meticulously crafted to perfectly work with our instruments, ensuring seamless compatibility and optimal performance. In addition to controlling the instruments, WinXPOW provides a comprehensive range of cutting-edge features. These include data reduction, profile fitting, pattern indexing, and spacegroup determination. Moreover, it boasts an array of powerful functionalities, such as advanced 2D and 3D graphics, among numerous other capabilities.

 

We provide a wide range of accessories to customize your sample environment according to your specific requirements. Our products encompass high temperature and reaction chambers, sample changers, dedicated battery cell holders, and various other accessories to enhance your experimentation capabilities.

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

- DSC 600 là thiết bị phân tích nhiệt lượng quét vi sai (DSC) thế hệ mới, được thiết kế để đáp ứng nhu cầu ngày càng cao trong các lĩnh vực nghiên cứu vật liệu, kỹ thuật hóa học, kiểm soát chất lượng, hóa dầu và dược phẩm. Với tấm dẫn nhiệt cải tiến, DSC 600 phát hiện chính xác ngay cả những thay đổi năng lượng nhỏ nhất, lý tưởng cho các phép đo enthalpy, chuyển pha thủy tinh, nhiệt kết tinh, độ tinh khiết và nhiệt dung riêng - Lò nung siêu nhẹ mang lại độ dẫn nhiệt và độ ổn định vượt trội trong dải nhiệt rộng. Thiết bị hỗ trợ nhiều loại tấm nhiệt chuyên dụng, giúp linh hoạt tối đa cho mọi nhu cầu kiểm tra trong phòng thí nghiệm. DSC 600 thể hiện sự chính xác, ổn định và tối ưu chi phí cho phân tích nhiệt chuyên sâu
Liên hệ

Hãng sx: ZonGon - Trung Quốc

Nồi hấp tiệt trùng cỡ nhỏ được sử dụng rộng rãi trong phòng thí nghiệm nghiên cứu sản phẩm mới của nhà máy, thí nghiệm tiệt trùng, viện nghiên cứu đại học...
Liên hệ

Hãng sx: ZonGon - Trung Quốc

Nồi hấp tiệt trùng cỡ nhỏ được sử dụng rộng rãi trong phòng thí nghiệm nghiên cứu sản phẩm mới của nhà máy, thí nghiệm tiệt trùng, viện nghiên cứu đại học...
Liên hệ

Hãng sx: ACA Systems - Phần Lan

ACA AX-100 là máy đo độ nhớt hiện đại, dựa trên nguyên lý mao dẫn, được thiết kế để đo độ nhớt phụ thuộc vào tốc độ cắt trong điều kiện quy trình thực tế. Nó cung cấp cho các nhà sản xuất lớp phủ dữ liệu họ cần để tối ưu hóa khả năng vận hành của máy phủ, khắc phục sự cố chất lượng và đẩy nhanh quá trình phát triển lớp phủ.
Liên hệ

Hãng sx: ACA Systems - Phần Lan

ACA Flow WR là máy phân tích bán tự động hiện đại dùng để đo khả năng giữ nước trong màu phủ. Máy hỗ trợ tối ưu hóa quy trình phủ, giúp xác định các vấn đề tương tác giữa lớp phủ và giấy nền, đồng thời cải thiện quá trình phát triển màu phủ và kiểm soát chất lượng tổng thể.
Liên hệ

Hãng sx: ACA Systems - Phần Lan

ACA Permi Lab là máy phân tích độ thấm khí nhanh và chính xác được thiết kế để thử nghiệm trong phòng thí nghiệm đối với các vật liệu bao bì làm từ sợi. Nó giúp các nhà sản xuất, nhà chuyển đổi và các nhóm R&D đánh giá khả năng bảo vệ của vật liệu chống lại không khí, độ ẩm và khí – các yếu tố quan trọng đối với thời hạn sử dụng, an toàn sản phẩm và hiệu suất vật liệu.
Liên hệ

Hãng sx: ACA Systems - Phần Lan

ACA RoQ là thiết bị di động và dễ sử dụng để đo độ cứng của từng cuộn giấy, màng nhựa. Thiết bị này lý tưởng cho cả cuộn giấy nguyên liệu, màng film nhựa trước khi cuộn và cuộn giấy thành phẩm.
Liên hệ

Hãng sx: Hunterlab - Mỹ

Máy đo màu di động MiniScan EZ 4500L có thiết kế 45 ° / 0 ° với màn hình lớn, trọng lượng nhẹ và được thiết kế công thái học để thao tác bằng một tay. Với phần mềm tích hợp bao gồm hầu hết các thang màu và chỉ số phản xạ công nghiệp chính. MiniScan EZ 4500 cho phép các nhà sản xuất đánh giá dễ dàng và chính xác chất lượng sản phẩm của mình.Hình học 45 ° / 0 ° với chế độ xem khu vực rộng lớn Trọng lượng nhẹ với tay cầm bọc cao su tạo sự thoải mái cho người vận hành Thao tác dễ dàng bằng một tay, điều hướng bằng đầu ngón tay cái của các chức năng Màn hình LCD lớn, dễ đọc Hiển thị dữ liệu màu, dữ liệu chênh lệch màu, biểu đồ màu, dữ liệu quang phổ, chênh lệch dữ liệu quang phổ, biểu đồ quang phổ, biểu đồ chênh lệch quang phổ Bao gồm tất cả các thang màu và chỉ số thường được sử dụng Lưu trữ 100 tiêu chuẩn và 800 phép đo mẫu.
Liên hệ

Hãng sx: Hunterlab - Mỹ

Thiết bị SpectraTrend HT của chúng tôi cung cấp các phép đo màu sắc và sắc thái không tiếp xúc có độ chính xác cao. Thiết bị cũng cung cấp dữ liệu màu liên tục, khiến thiết bị trở thành lựa chọn lý tưởng để sử dụng trong quá trình sản xuất nhằm xác định và hiệu chỉnh các biến thể màu sắc sớm nhất có thể. Khả năng thực hiện các thay đổi theo thời gian thực này giúp giảm thiểu lãng phí và các chi phí liên quan. Thiết bị cũng giúp bạn giảm khả năng giao các sản phẩm được làm từ lô thuốc nhuộm lỗi cho khách hàng.
Liên hệ

Hãng sx: Hunterlab - Mỹ

- Máy quang phổ đo màu CIE đo màu phản xạ và màu truyền qua - Dải bước sóng 350 nm - 1050 nm với độ phân giải quang học 5 nm và khoảng thời gian báo cáo - Hiệu chuẩn và kiểm soát UV tự động - Khoang truyền dẫn lớn mở ở ba mặt - Bao gồm phần mềm kiểm soát chất lượng (QC) EasyMatch
Liên hệ